Tion 1508 roof insulation contains requirements for roof insulation.
Minimum roof insulation r value ibc 2009.
For impact rated fenestration complying with section r301 2 1 2 of the irc or section 1608 1 2 of the ibc maximum u factor shall be 0 75 in zone 2 and 0 65 in zone 3.
For a very good introductory overview article on r value see r values over at the website of.
Similar increases were approved for walls.
The second r value applies when more than half the insulation is on the interior of the mass wall.
State only ma massachusetts 780 cmr chapter 13 5 r 30 state only mi michigan ashrae 90 1 2007 5 r 20 6 r 20 7 r 20 state only mn minnesota minnesota commercial state building code 6 r 30 7 r 35 please see disclaimer on back page.
The minimum ceiling insulation r values shall be r 19 in zones 1 through 4 and r 24 in zones 5 though 8.
The minimum wall r value shall be r 13 in all zones.
Or component performance alternative of section c402 1 5 roof solar reflectance and thermal emittance fenestration in building envelope.
Ibc 2009 uses the term roof covering to refer to a par ticular type of roofing product or system.
A minimum of fifty percent of the lamps in permanently installed lighting fixtures shall be high efficiency lamps.
R value of various materials.
The above deck roof insulation requirements previously at r 15 increased by 33 to r 20 in every climate zone in the u s.
Here s a handy r value table that covers most types of roof coverings building insulation and a few other materials.
Minimum insulation r value requirements non residential above roof deck.
The term is defined in section 1502 definitions as.
R value based method of section c402 1 3 u c and f factor based method of section c402 1 4.
You should of course see the manufacturer provided technical data sheet for the r value of specific products.
Table 402 1 1 insulation and fenestration requirements by componenta climate zone fenestration u factorb skylightb u factor glazed fenestration shgcb e ceiling r value wood frame wall r value mass wall r valuei floor r value.
The covering applied to the roof deck for weather resistance fire classification or appearance.
Where the roof sheathing is less than 3 4 inch 19 1 mm thick the nails.
Fasteners for asphalt shingles shall be galvanized stainless steel aluminum or copper roofing nails minimum 12 gage 0 105 inch 2 67 mm shank with a minimum 3 8 inch diameter 9 5 mm head of a length to penetrate through the roofing materials and a minimum of 3 4 inch 19 1 mm into the roof sheathing.
New wall s separating the sunroom from conditioned space shall meet the building thermal envelope requirements.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.