Metal roof shingles require a minimum roof pitch of 3 12 or greater.
Minimum roof slope ibc.
Minimum pitch for corrugated metal roof.
The ibc table 1505 1 lists the minimum requirements for roof covering fire resistance classifications a b or c for all types of.
For roof slopes from two units vertical in 12 units horizontal 17 percent slope and up to four units vertical in 12 units horizontal 33 percent slope underlayment shall be two layers applied in the following manner.
Minimum roof fire resistance ratings apply based on the type of construction and some building types do not require a fire rating.
The minimum slope for lapped nonsoldered seam metal roofs with applied lap sealant shall be one half unit vertical in 12 units horizontal 4 percent slope.
The minimum slope for standing seam of roof systems shall be one quarter unit.
The following table provides the minimum required allowable roof slope for each type of roofing material mentioned in the code.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
When required testing is in accordance with astm e108 or ul 790.
Just like other metal roofs the minimum pitch for a corrugated metal roof largely depends on the profile of the roof.
For standing seam metal roof panel systems a 1 4 12 minimum roof slope is prescribed.
For metal panel roof systems with nonsoldered seams with applied lap sealant ibc 2018 prescribes a 1 2 12 minimum roof slope.
Lap sealants shall be applied in accordance with the approved manufacturer s installation instructions.
This 1 4 12 minimum roof slope requirement also applies to spray polyurethane foam spf roof systems in new construction.
According to the 2012 international building code 1507 4 2 deck slope minimum slopes for roof panels need to comply with the following.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
The minimum roof slope allowed by code for any type of roof is in 12 applicable only to coal tar pitch roof systems.
Reroofing shall not be required to meet the minimum design slope requirement of one quarter unit vertical in 12 units horizontal 2 percent slope in section 1507 of the international building code for roofs that provide positive roof drainage.
Clay and concrete tile requires a minimum roof pitch of 2 1 2 12 or greater.
Apply a minimum 19 inch wide 483 mm strip of underlayment felt parallel with and starting at the eaves fastened sufficiently to hold in place.
The minimum slope for lapped non soldered seam metal roofs without applied lap sealant shall be three units vertical in 12 units horizontal 25 percent slope.